Fw: Urgent/Now : Got a Comfort Q !!!


  • To: ukha_d@xxxxxxx
  • Subject: Fw: Urgent/Now : Got a Comfort Q !!!
  • From: Gareth Cook <g@xxxxxxx>
  • Date: Wed, 19 Nov 2003 11:12:46 +0000
  • Mailing-list: list ukha_d@xxxxxxx; contact ukha_d-owner@xxxxxxx
  • Reply-to: ukha_d@xxxxxxx

Not sure I follow to be honest - i thought everything was in parallel
before

G.

Gareth Cook
SWG EMEA North Account Manager
IBM SWG - BTE Office - Lotus Park, Staines, TW18 3AG
Office: +44 (0)1784 445166 - Mobile: +44 (0)7980 445166
AIM Chat : TheBoyG - MSN Chat : chat@xxxxxxx
email: g@xxxxxxx


----- Forwarded by Gareth Cook/UK/IBM on 19/11/2003 11:03 -----

Discussion
Main Topic

"armagh_elect" <fmcalind@xxxxxxx>
Today 09:57

.
Subject:
.
Re: Fw: [ukha_d] Urgent/Now : Got a Comfort Q !!!
.
Category:



If using 6 core you can have the tampers connected seperately and
then connect all tampers together in the new alarm panel ( all in
series and a resistor ?)...But you should put the new END OF LINE
RESISTOR inside  the pirs ...in series with the alarm
contacts....Hope that makes sense...

Frank





--- In ukha_d@xxxxxxx, Gareth Cook <g@u...> wrote:
> ah ok - they PIRs that were in place had 6 core connected and the
new PIRs
> have 6 connections. So then do I NEED the tampers connected ?
>
> G.
>
>  Gareth Cook
>  SWG EMEA North Account Manager
>  IBM SWG - BTE Office - Lotus Park, Staines, TW18 3AG
>  Office: +44 (0)1784 445166 - Mobile: +44 (0)7980 445166
>  AIM Chat : TheBoyG - MSN Chat : chat@g...
>  email: g@xxxxxxx
>
>
> ----- Forwarded by Gareth Cook/UK/IBM on 19/11/2003 09:51 -----
>
> Discussion
> Main Topic
>
> "armagh_elect" <fmcalind@b...>
> Today 09:30
>
> .
> Subject:
> .
> Re: Fw: [ukha_d] Urgent/Now : Got a Comfort Q !!!
> .
> Category:
>
>
>
> Hi Gareth
>
>          EOL....End Of Line resistors ..which are normally located
> at the pir sensor...If using Tamper detections usually 2 resistors
> one across the alarm contact and one in series with the alarm
> contact and tamper switch (well thats how its done with
genesis)..sO
> ONLY NEED 4 CORE CABLE....
>
> HTH
> Frank
>
>
> --- In ukha_d@xxxxxxx, Gareth Cook <g@u...> wrote:
> > If I knew what that was I could answer :-(
> >
> > G.
> >
> >  Gareth Cook
> >  SWG EMEA North Account Manager
> >  IBM SWG - BTE Office - Lotus Park, Staines, TW18 3AG
> >  Office: +44 (0)1784 445166 - Mobile: +44 (0)7980 445166
> >  AIM Chat : TheBoyG - MSN Chat : chat@g...
> >  email: g@xxxxxxx
> >
> >
> > ----- Forwarded by Gareth Cook/UK/IBM on 19/11/2003 09:26 -----
> >
> > Discussion
> > Main Topic
> >
> > "Frank Mc Alinden" <fmcalind@b...>
> > Today 09:17
> >
> > .
> > Subject:
> > .
> > Re: [ukha_d] Urgent/Now : Got a Comfort Q !!!
> > .
> > Category:
> >
> >
> >
> > Does the New Alarm system have the same EOL Resistors as the
> Comfort ???
> > they might need to be replaced as well ???
> >
> > Just  a thought
> >
> > Frank
> >   ----- Original Message -----
> >   From: Gareth Cook
> >   To: ukha_d@xxxxxxx
> >   Sent: Wednesday, November 19, 2003 7:58 PM
> >   Subject: Fw: [ukha_d] Urgent/Now : Got a Comfort Q !!!
> >
> >
> >   Sort of. We're selling the house with an alarm, so I bought a
> Texe alarm
> >
> >   to replace the comfort. We've removed the comfort system and
> marked what
> >
> >   all the wires went into, but as yet Im having difficulty doing
a
> walk
> > test
> >   with just one PIR (Im replacing those too)...
> >
> >   And also our buyers are playing silly buggers and demanding to
> move in
> >   next monday - 4 days early. Our estate agent requested end of
> the month,
> >
> >   and so did their solicitor. Im pretty sure the guy (being a
bit
> &^%&$&)
> >   will pull out of the whole process.
> >
> >   So not the clearest of minds to be playing with an alarm
system !
> >
> >   G.
> >
> >   Gareth Cook
> >   SWG EMEA North Account Manager
> >   IBM SWG - BTE Office - Lotus Park, Staines, TW18 3AG
> >   Office: +44 (0)1784 445166 - Mobile: +44 (0)7980 445166
> >   AIM Chat : TheBoyG - MSN Chat : chat@g...
> >   email: g@xxxxxxx
> >
> >
> >   ----- Forwarded by Gareth Cook/UK/IBM on 19/11/2003 08:43 -----
> >
> >   Discussion
> >   Main Topic
> >
> >   "Paul Gale" <groups@s...>
> >   Today 08:26
> >
> >   .
> >   Subject:
> >   .
> >   RE: [ukha_d] Urgent/Now : Got a Comfort Q !!!
> >   .
> >   Category:
> >
> >
> >
> >   Gareth - have you sorted this now?
> >
> >   Paul.
> >
> >
> >   > -----Original Message-----
> >   > From: Gareth Cook [mailto:g@xxxxxxx]
> >   > Sent: 18 November 2003 19:17
> >   > To: ukha_d@xxxxxxx
> >   > Subject: [ukha_d] Urgent/Now : Got a Comfort Q !!!
> >   >
> >   > I'm ripping out Comfort (we're moving house) - but I have
a
> question -
> >
> >   how
> >   > on earth do I map the physical cables to the zones ? We've
> labelled
> > what
> >   > we've removed, but I can't see where it's listed what
these
> map to
> >   > internally. For example, Z1 on the PCB goes to what
> internally ? I've
> >   got
> >   > CS-Express but can't see a relation...
> >   >
> >   > If some KIND soul wouldn't mind giving me a call on my
mobile
> below ,
> >   > that'd be much appreciated :-)
> >   >
> >   > Cheers all
> >   >
> >   > G.
> >   >
> >   > (In NEED !)
> >   >
> >   >  Gareth Cook
> >   >  SWG EMEA North Account Manager
> >   >  IBM SWG - BTE Office - Lotus Park, Staines, TW18 3AG
> >   >  Office: +44 (0)1784 445166 - Mobile: +44 (0)7980 445166
> >   >  AIM Chat : TheBoyG - MSN Chat : chat@g...
> >   >  email: g@xxxxxxx
> >   >
> >   >
> >   >
> >   > [Non-text portions of this message have been removed]
> >   >
> >   >
> >   >
> >   > UKHA 2004: 15th and 16th May 2004
> >   >
> >   > http://www.automatedhome.co.uk
> >   > Post message: ukha_d@xxxxxxx
> >   > Subscribe:  ukha_d-subscribe@xxxxxxx
> >   > Unsubscribe:  ukha_d-unsubscribe@xxxxxxx
> >   > List owner:  ukha_d-owner@xxxxxxx
> >   >
> >   > Your use of Yahoo! Groups is subject to
> >   http://docs.yahoo.com/info/terms/
> >   >
> >   >
> >   >
> >
> >
> >
> >   UKHA 2004: 15th and 16th May 2004
> >
> >   http://www.automatedhome.co.uk
> >   Post message: ukha_d@xxxxxxx
> >   Subscribe:  ukha_d-subscribe@xxxxxxx
> >   Unsubscribe:  ukha_d-unsubscribe@xxxxxxx
> >   List owner:  ukha_d-owner@xxxxxxx
> >
> >   Your use of Yahoo! Groups is subject to
> > http://docs.yahoo.com/info/terms/
> >
> >
> >
> >
> >   [Non-text portions of this message have been removed]
> >
> >
> >         Yahoo! Groups Sponsor
> >
> >
> >
> >   UKHA 2004: 15th and 16th May 2004
> >
> >   http://www.automatedhome.co.uk
> >   Post message: ukha_d@xxxxxxx
> >   Subscribe:  ukha_d-subscribe@xxxxxxx
> >   Unsubscribe:  ukha_d-unsubscribe@xxxxxxx
> >   List owner:  ukha_d-owner@xxxxxxx
> >
> >   Your use of Yahoo! Groups is subject to the Yahoo! Terms of
> Service.
> >
> >
> > [Non-text portions of this message have been removed]
> >
> >
> >
> > UKHA 2004: 15th and 16th May 2004
> >
> > http://www.automatedhome.co.uk
> > Post message: ukha_d@xxxxxxx
> > Subscribe:  ukha_d-subscribe@xxxxxxx
> > Unsubscribe:  ukha_d-unsubscribe@xxxxxxx
> > List owner:  ukha_d-owner@xxxxxxx
> >
> > Your use of Yahoo! Groups is subject to
> http://docs.yahoo.com/info/terms/
> >
> >
> >
> >
> > [Non-text portions of this message have been removed]
>
>
>
> UKHA 2004: 15th and 16th May 2004
>
> http://www.automatedhome.co.uk
> Post message: ukha_d@xxxxxxx
> Subscribe:  ukha_d-subscribe@xxxxxxx
> Unsubscribe:  ukha_d-unsubscribe@xxxxxxx
> List owner:  ukha_d-owner@xxxxxxx
>
> Your use of Yahoo! Groups is subject to
http://docs.yahoo.com/info/terms/
>
>
>
>
> [Non-text portions of this message have been removed]



UKHA 2004: 15th and 16th May 2004

http://www.automatedhome.co.uk
Post message: ukha_d@xxxxxxx
Subscribe:  ukha_d-subscribe@xxxxxxx
Unsubscribe:  ukha_d-unsubscribe@xxxxxxx
List owner:  ukha_d-owner@xxxxxxx

Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/




[Non-text portions of this message have been removed]



Home | Main Index | Thread Index

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.