Thanks for all your help guys, thats just what I needed to know.
Thanks
Mark
--- In ukha_d@xxxxxxx, "Paul Gale" <groups@s...> wrote:
> Long post coming up!!!
>=20
> This is the 'Serial Data Input' code for serial port 3 (extra=20
serial port on HV):
>=20
> Serial port 3: Put binary value of received serial=20
character # 1 into Result Value
> Var #43 (Test - serial char 1) =3D Result Value
> Serial port 3: Put binary value of received serial=20
character # 2 into Result Value
> Var #44 (Test - serial char 2) =3D Result Value
> Serial port 3: Put binary value of received serial=20
character # 3 into Result Value
> Var #45 (Test - serial char 3) =3D Result Value
> Serial port 3: Put binary value of received serial=20
character # 4 into Result Value
> Var #46 (Test - serial char 4) =3D Result Value
> Serial port 3: Put binary value of received serial=20
character # 5 into Result Value
> Var #47 (Test - serial char 5) =3D Result Value
> Serial port 3: Put binary value of received serial=20
character # 6 into Result Value
> Var #48 (Test - serial char 6) =3D Result Value
> Serial port 3: Put binary value of received serial=20
character # 7 into Result Value
> Var #49 (Tset - serial char 7) =3D Result Value
> Serial port 3: Put number of received serial=20
characters into Result Value
> Var #1 (Serial Buffer Size) =3D Result Value
> Serial port 3: Put binary value of received serial=20
character # 1 into Result Value
> Var #2 (First Serial Character) =3D Result Value
> Var #3 (Var 3) =3D var #2 (First Serial Character)
> If
> ; If first character is the STX character (Ctrl-C)
> Var #2 (First Serial Character) =3D 3
> Then
> ; Comfort Command or Status Report
> Var #4 (Test - Location) =3D 10
> If
> ; If we get NA, we're not logged in, so log in
> Serial port 3: Serial input characters number 2=20
through 3 are 'NA'
> Then
> ; Log in using macro
> Var #4 (Test - Location) =3D 11
> Do macro #0 (Comfort login) once
> Set flag #0 (Done login)
> Else
> ; Determine the status code and act on it
> Var #4 (Test - Location) =3D 12
> If
> Serial port 3: Serial input characters number 2=20
through 3 are 'IP'
> Then
> ; Zone sensor activated
> ; Get zone number - it's in ASCII Hex format -=20
change to decimal
> Var #4 (Test - Location) =3D 13
> Serial port 3: Put binary value of received serial=20
character # 4 into Result Value
> Var #6 (Serial Character 1) =3D Result Value
> Serial port 3: Put binary value of received serial=20
character # 5 into Result Value
> Var #7 (Serial Character 2) =3D Result Value
> Do macro #1 (Hex digits to decimal number) once
> ; Decimal value returned in variable 'Result of HEX-
DECIMAL conv.'
> If
> ; If input reported by Comfort is a light (1-27), do=20
lighting macro
> Var #8 (Result of HEX-DECIMAL conv.) < 28
> Then
> If
> ; Actions for zone ON status
> Serial port 3: Serial input characters number 7=20
through 7 are '1'
> Then
> Var #4 (Test - Location) =3D 16
> ; Add the offset (10) to the Zone Number to activate=20
the Macro
> Var #9 (Lighting Macro Number) =3D var #8 (Result of=20
HEX-DECIMAL conv.)
> Var #9 (Lighting Macro Number) =3D var #9 (Lighting=20
Macro Number) + 10
> Do macro at variable #9 (Lighting Macro Number) once
> End If
> If
> ; Actions for zone OFF status
> Serial port 3: Serial input characters number 7=20
through 7 are '0'
> Then
> Var #4 (Test - Location) =3D 17
> End If
> End If
> If
> ; If input is 3rd button on keyfob (house symbol)
> Var #8 (Result of HEX-DECIMAL conv.) =3D 31
> Then
> If
> ; Action for ON
> Serial port 3: Serial input characters number 7=20
through 7 are '1'
> Then
> Do macro #56 (Open/Close Garage Door) once
> End If
> End If
> If
> ; If input is 4th button on keyfob (Light symbol)
> Var #8 (Result of HEX-DECIMAL conv.) =3D 30
> Then
> If
> ; Action for ON
> Serial port 3: Serial input characters number 7=20
through 7 are '1'
> Then
> Do macro #57 (Lights for keyfob) once
> End If
> End If
> End If
> If
> ; Alarm mode change received (M? from query, MD from=20
actual change)
> Serial port 3: Serial input characters number 2=20
through 3 are 'M?'
> Or Serial port 3: Serial input characters number 2=20
through 3 are 'MD'
> Then
> Serial port 3: Put value of received serial=20
character # 5 into Result Value
> Var #40 (Comfort Alarm ARM Status) =3D Result Value
> If
> ; Only do this on ACTUAL state change
> Serial port 3: Serial input characters number 2=20
through 3 are 'MD'
> Then
> Do macro #45 (Alarm state change detected) once
> End If
> End If
> If
> Serial port 3: Serial input characters number 2=20
through 3 are 'C?'
> Or Serial port 3: Serial input characters number 2=20
through 3 are 'CT'
> Then
> ; Counter value report - for SmartFit Heating
> Var #4 (Test - Location) =3D 18
> If
> ; Room Temperature Report
> Serial port 3: Serial input characters number 4=20
through 5 are '00'
> Then
> ; Convert Hex temperature to Decimal
> Var #4 (Test - Location) =3D 19
> Serial port 3: Put binary value of received serial=20
character # 6 into Result Value
> Var #6 (Serial Character 1) =3D Result Value
> Serial port 3: Put binary value of received serial=20
character # 7 into Result Value
> Var #7 (Serial Character 2) =3D Result Value
> Do macro #1 (Hex digits to decimal number) once
> Var #37 (Room Temperature) =3D var #8 (Result of HEX-
DECIMAL conv.)
> End If
> If
> ; Hot Water Temperature Report
> Serial port 3: Serial input characters number 4=20
through 5 are '01'
> Then
> ; Convert Hex temperature to Decimal
> Var #4 (Test - Location) =3D 20
> Serial port 3: Put binary value of received serial=20
character # 6 into Result Value
> Var #6 (Serial Character 1) =3D Result Value
> Serial port 3: Put binary value of received serial=20
character # 7 into Result Value
> Var #7 (Serial Character 2) =3D Result Value
> Do macro #1 (Hex digits to decimal number) once
> Var #38 (Hot Water Temperature) =3D var #8 (Result of=20
HEX-DECIMAL conv.)
> End If
> End If
> End If
> Else
> End If
> Wait 0:00:05.00 with timer #26 (Test Timer), Then:
> Var #4 (Test - Location) =3D 0
> End Wait
>=20
> This is an example of some of the serial commands received and=20
acted upon. The hex to decimal conversion macro is:
>=20
> MACRO EVENT # 1 'Hex digits to decimal number'
>=20
> ; Converts Hex ASCII digits to decimal
> Var #7 (Serial Character 2) =3D var #7 (Serial=20
Character 2) - 48
> If
> Var #7 (Serial Character 2) > 9
> Then
> Var #7 (Serial Character 2) =3D var #7 (Serial=20
Character 2) - 7
> End If
> Var #6 (Serial Character 1) =3D var #6 (Serial=20
Character 1) - 48
> Var #6 (Serial Character 1) =3D var #6 (Serial=20
Character 1) =D7 2
> Var #6 (Serial Character 1) =3D var #6 (Serial=20
Character 1) =D7 2
> Var #6 (Serial Character 1) =3D var #6 (Serial=20
Character 1) =D7 2
> Var #6 (Serial Character 1) =3D var #6 (Serial=20
Character 1) =D7 2
> Var #7 (Serial Character 2) =3D var #7 (Serial=20
Character 2) + var #6 (Serial Character 1)
> Var #8 (Result of HEX-DECIMAL conv.) =3D var #7=20
(Serial Character 2)
>=20
> The Comfort login macro: (not actually used much as the UCM stays=20
logged in - ACE deals with this anyway)
>=20
>=20
> MACRO EVENT # 0 'Comfort login'
>=20
> Var #5 (Comfort Control Character) =3D 3
> Serial port 3 transmit: Variable #5 (Comfort Control=20
Character) value as 1 binary byte
> Serial port 3 transmit: "LIxxxxxx"
> Var #5 (Comfort Control Character) =3D 13
> Serial port 3 transmit: Variable #5 (Comfort Control=20
Character) value as 1 binary byte
>=20
> Where 'xxxxxx' is your login code.
>=20
> I also have a macro which is called by any security mode changes -=20
let me know if you want that and I'll send off list (for security=20
reasons obviously!)
>=20
> Paul.
>=20
>=20
>=20
> -----Original Message-----
> From: Mark McCall [mailto:lists@a...]=20
> Sent: 11 November 2003 09:09
> To: ukha_d@xxxxxxx
> Subject: Re: [ukha_d] HomeVision and Comfort users
>=20
> > I then have a Comfort serial UCM talking directly to one of
the=20
serial
> > ports on HV Pro - HV then listens to the serial messages
>=20
> Paul
>=20
> How big a job is it writing the macros to allow HV to decode the=20
serial
> commands coming from Comfort? Can you cut and paste an example or=20
two?
>=20
> Thanks
>=20
> M.
>=20
>=20
>=20
>=20
> UKHA 2004: 15th and 16th May 2004
>=20
> http://www.automatedhome.co.uk=20
> Post message: ukha_d@xxxxxxx=20
> Subscribe: ukha_d-subscribe@xxxxxxx=20
> Unsubscribe: ukha_d-unsubscribe@xxxxxxx=20
> List owner: ukha_d-owner@xxxxxxx=20
>=20
> Your use of Yahoo! Groups is subject to=20
http://docs.yahoo.com/info/terms/
Home |
Main Index |
Thread Index
|