The UK Home Automation Archive

Archive Home
Group Home
Search Archive


Advanced Search

The UKHA-ARCHIVE IS CEASING OPERATIONS 31 DEC 2024


[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

RE: Clipsal C-bus was Re: **** UKHA2003 - Pictures! ****


  • To: <ukha_d@xxxxxxx>
  • Subject: RE: Clipsal C-bus was Re: **** UKHA2003 - Pictures! ****
  • From: "Dave McLaughlin" <dave@xxxxxxx>
  • Date: Mon, 19 May 2003 00:10:24 +0100
  • Mailing-list: list ukha_d@xxxxxxx; contact ukha_d-owner@xxxxxxx
  • Reply-to: ukha_d@xxxxxxx

Hi Frank,

>Yes it would be a wee bit expensive to fly to Melbourne ....

But worth it though!!

>LOL .....You mus think i live in Ramsey street ;-))
>The only time we have a pool in my place when theres
>a heavy shower of rain...(and it floods my little shed ;-(( ).

LOL... The guys I know from my trip to Bathurst, most of them
have pools and the one in Brisbane is superb.

>Are you going ahead with a lighting setup or doing your own ???

Two things are stopping me. One is SWMBO does not like the
switches (I love them) and the second is that they will let
me install it all myself but it has to be commissioned by
them which is going to make it expensive.

I have therefore started my own design to work with a 4 wire
link instead of the 2 that C-bus uses. This will use +12-24V
power on one pair and CAN bus in the other pair. I plan to
have retrofit PCB's that go in behind the existing switches
and send the commands via the bus. No mains wiring required
within the switch box. Not the best solution but workable
with that SWMBO wants. I want to design some non-contact
switches using the Qprox sensors (I have a couple of 6 way
devices to try out) that go behind plain white blanking
plates with etched/engraved controls on the front. Just an
idea at the moment until I see how it works.

I have started the design of an 8 way dimmer module and a
4 way relay module. Same idea as C-bus but in different
boxes. I'll be putting some details up this week on the
website so will let you know when it is updated.

Regards for now
Dave...

---
Outgoing mail is certified Virus Free.
Checked by AVG anti-virus system (http://www.grisoft.com).
Version: 6.0.478 / Virus Database: 275 - Release Date: 06/05/2003





Home | Main Index | Thread Index