Re: Genesis To C_Bus



> Kevin is badgering me to get a home vision unit! I'm not sure I have
the
> time to use all its functionality! :-)

You will not regret it if you do get it believe me.....Im using the ir
function and some custom screens but havnt scratched the surface...its a
gradual thing and programming is easy......Theres an installation in
melbourne which has Homevision, C_bus + Comfort all talking to one
another...........

You could have bought Homevision almost  with the money you spend on that
plasma friendly ir receiver ;-)) Hows the ir system going ?

Frank

----- Original Message -----
From: "Rob Mouser" <rmouser@xxxxxxx>
To: <ukha_d@xxxxxxx>
Sent: Sunday, March 02, 2003 9:34 AM
Subject: RE: [ukha_d] Genesis To C_Bus


> Yep scenes are no problem in the c-touch units. The graphical sliders
> move in real time too!
>
> Yes comfort will do scheduled events, although I have not used for
such.
> I find the Comfigurator software for Comfort cumbersome to programme.
> Basic scheduling of c-bus actions are available in c-touch too. But no
> if/then/else type logic.
>
> Kevin is badgering me to get a home vision unit! I'm not sure I have
the
> time to use all its functionality! :-)
>
> I do have an IR zone controller though!
>
> Rob
>
> -----Original Message-----
> From: Frank Mc Alinden [mailto:armagh@xxxxxxx]
> Sent: 01 March 2003 22:30
> To: ukha_d@xxxxxxx
> Subject: Re: [ukha_d] Genesis To C_Bus
>
>
> Hi Rob
>
>
> >The c-touch units can now emulate the Comfort key pads, which is
one
> >v.nice function. Also you can use standard c-bus switches to
control
> >Comfort functions. (i.e Arm, Disarm, Panic maybe.)
>
> Sounds good ;-)) I believe you can also program scenes with the
C_Touch
> panels  ??
>
> Dont think i would use standard switches to Disarm the Alarm system
> though ..
>
> Do you use Comfort for your scheduled events eg...if later than
10:00pm
> AND external pir is tripped turn on security lights for 10 minutes
..etc
> etc
>
> Frank
>
> ----- Original Message -----
> From: "Rob Mouser" <rmouser@xxxxxxx>
> To: <ukha_d@xxxxxxx>
> Sent: Sunday, March 02, 2003 9:08 AM
> Subject: RE: [ukha_d] Genesis To C_Bus
>
>
> > Hi Frank
> >
> > The c-touch units can now emulate the Comfort key pads, which is
one
> > v.nice function. Also you can use standard c-bus switches to
control
> > Comfort functions. (i.e Arm, Disarm, Panic maybe.) You also have
the
> > functionality that Comfort can send responses based on a c-bus
state.
> > Those repines could be x10, IR or relay for example. One example
I
> > have here at home is that I have a couple of x-10 appliance
switches
> > that are switched on and off via a c-bus switch. In essence you
have:
> > C-bus - Comfort - x10.
> >
> > Rob Mouser
> >
> >
> >
> >
> >
> > -----Original Message-----
> > From: Frank Mc Alinden [mailto:armagh@xxxxxxx]
> > Sent: 01 March 2003 20:08
> > To: ukha_d@xxxxxxx
> > Subject: Re: [ukha_d] Genesis To C_Bus
> >
> >
> > Thanks Rob
> >
> > What sort of application would you use C_bus to control Comfort
?? Im
> > using a C_bus relay to turn on my Genesis alarm panel ........
> >
> > Frank
> >
> >
> >
> > ----- Original Message -----
> > From: "Rob Mouser" <rmouser@xxxxxxx>
> > To: <ukha_d@xxxxxxx>
> > Sent: Saturday, March 01, 2003 9:28 PM
> > Subject: RE: [ukha_d] Genesis To C_Bus
> >
> >
> > > My smoke detectors are 12v units linked to a zone in
comfort. When
> > > that zone is triggered Comfort is programmed to send a c-bus
command
>
> > > to turn certain c-bus groups on, a timer then turns it off
and visa
> > > versa, finally when the alarm is disarmed another response
stops the
>
> > > process. Comfort response codes look like this, you will
notice that
>
> > > the flash responses call other responses that actually turn
lights
> > > on and off: (Note the two ** are purely to help me sort my
responses
>
> > > so they are simpler to find in comfigurator.)
> > >
> > > Response=**Flash Lights On
> > > Do Kit-Lights-On [**C-BUS Kitchen Lights On]
> > > Do Hall-Lights-On [**C-BUS Hall Lights On]
> > > Do Land-Lights-On [**C-BUS Landing Lights On]
> > > Do FlashLights-Off [**Flash Lights Off] After 5 Seconds
Using
> > > Timer07
> > >
> > > Response=**Flash Lights On
> > > Do Kit-Lights-Off [**C-BUS Kitchen Lights Off]
> > > Do Hall-Lights-Off [**C-BUS Hall Lights Off]
> > > Do Land-Lights-Off [**C-BUS Landing Lights Off]
> > > Do FlashLights-On [**Flash Lights On] After 5 Seconds Using
Timer07
> > >
> > > And to stop it all:
> > >
> > > Response=**Stop Flashing Lights
> > > Stop Timer Timer07
> > >
> > >
> > > HTH
> > >
> > > Rob Mouser
> > >
> > >
> > >
> > > Hi Rob
> > >
> > > > Good news Frank!
> > >
> > > Certainly is ;-))  Was talking to Kevin about the C_Bus ir
learning
> > > module...
> > >
> > > very expensive.......
> > >
> > >      Just a quick C_Bus question....
> > >
> > > How did you make your lights flash on + off when your smoke
> > > detectors tripped..????
> > >
> > > Frank
> > > ----- Original Message -----
> > > From: "Rob Mouser" <rmouser@xxxxxxx>
> > > To: <ukha_d@xxxxxxx>
> > > Sent: Saturday, March 01, 2003 8:58 PM
> > > Subject: RE: [ukha_d] Genesis To C_Bus
> > >
> > >
> > > > Good news Frank!
> > > > And with Kevin's hard work on xAP for c-bus this
further
> > > > strengthens
> >
> > > > its position. Certainly the Comfort C-bus UCM works
very well and
> > > > operability in both directions (i.e. C-bus controlling
Comfort and
>
> > > > Comfort controlling
> > > > C-bus.) works very well. Just a shame that Comfort is
so
> > > > cumbersome to
> > >
> > > > programme even with comfigurator.
> > > >
> > > > Cheers
> > > >
> > > > Rob
> > > >
> > > > -----Original Message-----
> > > > From: Frank Mc Alinden [mailto:armagh@xxxxxxx]
> > > > Sent: 01 March 2003 07:08
> > > > To: ukha_d@xxxxxxx
> > > > Subject: [ukha_d] Genesis To C_Bus
> > > >
> > > >
> > > > Hi All
> > > >         Today i was talking to the Genesis tech from
Brisbane and
> > > > he
> >
> > > > was telling me that the C_Bus guy from Hayman
Integrated Systems (
>
> > > > belongs to Gerard Industries) got Genesis sending
lighting
> > > > commands to
> > >
> > > > the C_Bus system and was impressed how easy it was to
do so . You
> > > > can program Text Messages (100 off from memory) into
Genesis which
>
> > > > can be sent whenever an event or condition occurs to
either a
> > > > keypad
> >
> > > > OR  to any of the Genesis add on modules... ie 2 door
access
> > > > controller( via rs485
> > > > network)  and these devices have a serial port which i
assume you
> > > > connect a C_bus pc interface ....It appears the C_bus
commands are
>
> > > > ASCII... Genesis people have applied for the C_Bus
protocol and
> > > > its
> > > been
> > > > approved so I'm hoping it comes through soon..
> > > >
> > > >
> > > > Frank Mc
> > > >
> > > > [Non-text portions of this message have been removed]
> > > >
> > > >
> > > >
> > > > http://www.automatedhome.co.uk
> > > > Post message: ukha_d@xxxxxxx
> > > > Subscribe:  ukha_d-subscribe@xxxxxxx
> > > > Unsubscribe:  ukha_d-unsubscribe@xxxxxxx
> > > > List owner:  ukha_d-owner@xxxxxxx
> > > >
> > > > Your use of Yahoo! Groups is subject to
> > > > http://docs.yahoo.com/info/terms/
> > > >
> > > >
> > > >
> > > >
> > > > http://www.automatedhome.co.uk
> > > > Post message: ukha_d@xxxxxxx
> > > > Subscribe:  ukha_d-subscribe@xxxxxxx
> > > > Unsubscribe:  ukha_d-unsubscribe@xxxxxxx
> > > > List owner:  ukha_d-owner@xxxxxxx
> > > >
> > > > Your use of Yahoo! Groups is subject to
> > > > http://docs.yahoo.com/info/terms/
> > > >
> > > >
> > >
> > >
> > > http://www.automatedhome.co.uk
> > > Post message: ukha_d@xxxxxxx
> > > Subscribe:  ukha_d-subscribe@xxxxxxx
> > > Unsubscribe:  ukha_d-unsubscribe@xxxxxxx
> > > List owner:  ukha_d-owner@xxxxxxx
> > >
> > > Your use of Yahoo! Groups is subject to
> > > http://docs.yahoo.com/info/terms/
> > >
> > >
> > >
> > >
> > > http://www.automatedhome.co.uk
> > > Post message: ukha_d@xxxxxxx
> > > Subscribe:  ukha_d-subscribe@xxxxxxx
> > > Unsubscribe:  ukha_d-unsubscribe@xxxxxxx
> > > List owner:  ukha_d-owner@xxxxxxx
> > >
> > > Your use of Yahoo! Groups is subject to
> > > http://docs.yahoo.com/info/terms/
> > >
> > >
> >
> >
> >
> > http://www.automatedhome.co.uk
> > Post message: ukha_d@xxxxxxx
> > Subscribe:  ukha_d-subscribe@xxxxxxx
> > Unsubscribe:  ukha_d-unsubscribe@xxxxxxx
> > List owner:  ukha_d-owner@xxxxxxx
> >
> > Your use of Yahoo! Groups is subject to
> > http://docs.yahoo.com/info/terms/
> >
> >
> >
> >
> > http://www.automatedhome.co.uk
> > Post message: ukha_d@xxxxxxx
> > Subscribe:  ukha_d-subscribe@xxxxxxx
> > Unsubscribe:  ukha_d-unsubscribe@xxxxxxx
> > List owner:  ukha_d-owner@xxxxxxx
> >
> > Your use of Yahoo! Groups is subject to
> > http://docs.yahoo.com/info/terms/
> >
> >
>
>
>
> http://www.automatedhome.co.uk
> Post message: ukha_d@xxxxxxx
> Subscribe:  ukha_d-subscribe@xxxxxxx
> Unsubscribe:  ukha_d-unsubscribe@xxxxxxx
> List owner:  ukha_d-owner@xxxxxxx
>
> Your use of Yahoo! Groups is subject to
> http://docs.yahoo.com/info/terms/
>
>
>
>
> http://www.automatedhome.co.uk
> Post message: ukha_d@xxxxxxx
> Subscribe:  ukha_d-subscribe@xxxxxxx
> Unsubscribe:  ukha_d-unsubscribe@xxxxxxx
> List owner:  ukha_d-owner@xxxxxxx
>
> Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/
>
>


http://www.automatedhome.co.uk
Post message: ukha_d@xxxxxxx
Subscribe:  ukha_d-subscribe@xxxxxxx
Unsubscribe:  ukha_d-unsubscribe@xxxxxxx
List owner:  ukha_d-owner@xxxxxxx

Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/