Yep :-)

Keith

www.diyha.co.uk
www.kat5.tv


> -----Original Message-----
> From: Paul Robinson [mailto:ukcueman@xxxxxxx]
> The wiring is done using 2 of the 4 pairs. Orange and blue
> are connected to the positive terminals and white/orange
> and white/blue connected to negative.
>
> There's also a single "network burden" that must be
> connected. This wires a
> 10uF capacitor and 1k resistor in series between the +ve and
> -ve sides.
>
> I guess that does mean that what goes up one leg of a pair
> comes down the other.
>