RE: Mv1000 cont...



Good question...

The new cameras I bought are colour during the light then turn B&W
during darkness...

What would this do.....

I will still be happy with ANY pictures at this stage..

B.

-----Original Message-----
From: Paul Gale [mailto:groups@xxxxxxx]
Sent: 21 August 2003 22:34
To: ukha_d@xxxxxxx
Subject: RE: [ukha_d] Mv1000 cont...


Not followed this thread much but I connect 3 B+W cams and 1 colour into my
MV1000. The colour cam shows up in B+W through it though. TBH I've not had
much time to troubleshoot (could be down to my home made video amp circuit)
but was wondering if the MV1000 will only support ALL B+W or ALL colour
cams, not a mix????  Anyone got both working simultaneously?

Paul.



-----Original Message-----
From: Brian G. Reynolds [mailto:brian.g.reynolds@xxxxxxx]
Sent: 21 August 2003 22:10
To: ukha_d@xxxxxxx
Subject: RE: [ukha_d] Mv1000 cont...



I have now reset back to the factory defaults, re configured and still
nothing.

I tried a cross over cable to a stand alone PC that is on the same subnet
mask etc but still nothing.

I have tried different cat5 cables, nothing...

I think I have bought a duff Mv1000....bugger...

Good whilst it lasted.....

B.

-----Original Message-----
From: Brian G. Reynolds
Sent: 21 August 2003 18:40
To: Ukha_D (E-mail)
Subject: RE: [ukha_d] Mv1000 cont...


I could try that......if I could get the thing to work at all now!

I think I might use a crossover cable and connect it straight to a PC and
see if that works....

Thanks anyway....still trying...

B.

PS sorry but can not email you direct, have to send to the group...


-----Original Message-----
From: Paul Smith [mailto:wheelbarrowhandle@xxxxxxx]
Sent: 21 August 2003 07:52
To: Brian G. Reynolds
Subject: RE: [ukha_d] Mv1000 cont...


Hi Brian,


It looks like the mv1000 is redetecting cameras every 60 seconds.
This maybe why you can't see them.


I think it's on the camera page that you can set the re detect option. Try
changing it to a much bigger figure. Or for now disable it.


Regards,


Paul


-----Original Message-----
From: Brian G. Reynolds [mailto:brian.g.reynolds@xxxxxxx]
Sent: 20 August 2003 20:28
To: ukha_d@xxxxxxx
Subject: RE: [ukha_d] Mv1000 cont...

Ignore last posting, the direct posting was returned direct back to me!!!!

that is the third NTL email address I can not email too!

So I will paste the code below, my apologies to other users.

B.




System page at p0003b000 (vff910000)
Raminfo
addr:0003c000 size:0005fc00 addr:00100000 size:00700000
Boxinfo
cpu:000001e6 fpu:000001e7 cpu_flags:00000075 cpu_speed:00001634
ram_size:0079bc00 hw_flags:00000040 cpu_id:AMD 486DX4 F4M8S4
real_addr:ff800000
Displayinfo
primary:0000 secondary:0000 cg_table: 00000000 00000000 00000000
00000000 00000000 00000000 00000000 00000000 00000000 00000000
Diskinfo
ndisks:0000
0000)  ncyl:0000 nhead:0000 nsect:0000
0001)  ncyl:0000 nhead:0000 nsect:0000
0002)  ncyl:0000 nhead:0000 nsect:0000
0003)  ncyl:0000 nhead:0000 nsect:0000
Qtime
sec:3eab3cd1 cycles_per_sec:001234de clk8254:31f451f1
Osinfo
nodename:node1 nodenum:0001
Bootinfo
user_sys_ptr:ff910000 ker_sys_ptr:ff911000 sys_size:00000c70
image_addr:00006000 image_size:00035000 dir_addr:00006000
args_addr:00000000
kern_addr:ff920000 kern_size:0001d440 user_addr:00400000
user_size:bfc00000
kstack_addr:ffc00000 mmgr_addr:c0000000 mmgr_size:3f800000
user_addr_end:00bfffff user_align:00400000

Devm.tx486: Mv-Engine FFS Device driver (c) Active Imaging (UK) Ltd.
Devm.tx486: V2.11 (Compiled on May 07 1998 @ 14:36:36)

Retrying open utility semaphoreMqueue handler running.
OK

Pty handler running.
Serial handler running.
Aug 20 20:00:19  syslogd: restart
























MV1000 (Rev 2.10)
HIT ANY KEY WITHIN 10 SECONDS TO TELL ME YOU'RE THERE:

Ok, byebye

Aug 20 20:00:36 nto Mv1000: WDOG:Enabling watchdog
Aug 20 20:00:38 nto Mv1000: HTTPD:Starting about thread
Aug 20 20:00:38 nto Mv1000: ACQD:Detecting cameras
Aug 20 20:00:39 nto Mv1000: IFACE:Mv1000 Ethernet
setting route to 192.168.1.3
Aug 20 20:00:41 nto Mv1000: ACQD:Camera detected on channel 1
Aug 20 20:00:44 nto Mv1000: ACQD:Camera detected on channel 2
Aug 20 20:00:47 nto Mv1000: ACQD:No camera detected on channel 3
Aug 20 20:00:50 nto Mv1000: ACQD:No camera detected on channel 4
Aug 20 20:00:53 nto Mv1000: ACQD:No camera detected on channel 5
Aug 20 20:00:56 nto Mv1000: ACQD:No camera detected on channel 6
Aug 20 20:00:56 nto Mv1000: ACQD:Complete
Aug 20 20:00:56 nto Mv1000: ACQD:Loading configuration
Aug 20 20:01:01 nto Mv1000: ACQD:Complete
Aug 20 20:01:01 nto Mv1000: HTTPD:Waiting to accept connection
Aug 20 20:01:38 nto Mv1000: ACQD:Camera redetected on channel  1
Aug 20 20:01:38 nto Mv1000: ACQD:Camera redetected on channel  2
Aug 20 20:02:38 nto Mv1000: ACQD:Camera redetected on channel  1
Aug 20 20:02:38 nto Mv1000: ACQD:Camera redetected on channel  2