The UK Home Automation Archive

Archive Home
Group Home
Search Archive


Advanced Search

The UKHA-ARCHIVE IS CEASING OPERATIONS 31 DEC 2024

Latest message you have seen: RE: Video: Unboxing the Ubiquiti UniFi Wi-Fi Access Point


[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: Re: C-Bus and Wire-wound transformers - HELP



Hi Bruno
Im using 50w LV  halogen lamps with individual transformers on my C_Bus
setup and i only notice a noise  when the lamps are initially turned on
..not a continual humming noise (unless im going deaf)...

Frank

----- Original Message -----
From: Bruno Prior
To: ukha_d@xxxxxxx
Sent: Saturday, August 16, 2003 8:31 AM
Subject: Re: [ukha_d] Re: C-Bus and Wire-wound transformers - HELP


We're already using HV halogens downstairs in the brick barn (the only
part of the buildings where we have a suspended ceiling and were
therefore able to use recessed spots). I don't have a problem with their
colour temperature, although the rooms are currently bare, so they don't
have a comfortable feel to them anyway. But the silence and easy
dimmability are priceless.

I don't think a bigger dimmer will help. We already have the 2A dimmers
for the 300W loads, so we've got plenty of headroom. We've had plenty of
detailed advice from Clipsal and they haven't suggested that a bigger
dimmer would help, so I'm guessing it wouldn't.

As I say, it looks like the best conclusion is not to use series LV
lighting with C-Bus. Individual LV lamps with small transformers might
be alright, but I'm betting you'd still get a buzz from them on dim.

We don't have to use HV halogen. I could go for a fibre-optic solution.
But I don't think I'll get the lumens that way, so I'll probably stick
with HV halogen.

Cheers,

Bruno


David Buckley wrote:
> --- In ukha_d@xxxxxxx, Bruno Prior <bruno@r...> wrote:
>
>>As a follow-up, for everyone's information, it seems that Clipsal
>
> do not
>
>>recommend transformers above 105VA for use with C-Bus dimmers.
>
>
> Have Clipsal not recommended a bigger dimmer, rather than the small
> multichannel din rail (1A / 2A) dimmers?  A single L5101D20 dimmer
> will eat your 300W load for breakfast, but may or may not solve the
> buzz.  But it is a CBus component, and would let you keep your LV
> halogens and hiwire.
>
> I'd do almost anything to avoid using HV halogens; I find their
> colour temperature horrible!



Home | Main Index | Thread Index

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.