The UK Home Automation Archive

Archive Home
Group Home
Search Archive


Advanced Search

The UKHA-ARCHIVE IS CEASING OPERATIONS 31 DEC 2024

Latest message you have seen: RE: (ukha_d) Homeseer/CID/Meteor


[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

RE: Unrecognised X-10 log entries



Mark Harrision said:
>Actually, and this is serious...

>Don't look at next door - look at the THIRD house down (in each direction!)

Good advice (as usual!) Mark; however where I live the houses aren't
neatly regimented - but we have overhead lines so I should be able to
identify the right ones...

(For those in the dark, the implication is that in a planned
development, houses will be arranged on the three phases in turn, so
the third house along will be on the same phase as you - and X-10
doesn't jump phases without a coupler)

Using a different piece of software I was able to search for other
computer interfaces and found none. However, the help notes suggest
that Windows machines don't necessarily respond to this request...

...thinks - is what I've just done a 'Hail Request' command?

==============================

Justin said:
>My Powermax only sends 1 command when armed/disarmed. The fact that yours
>sends 2 commands roughly 30 seconds apart seems suspicious. As the spurious

It confuse me too till I realised out that the two commands are:
1) During the delay period (currently 30s) before arming
2) Start of armed period
(I have B1 set for both parameters as I was too impatient to wait for
the delay to get an indication of arming!)

>X10 info is only sent when the alarm is armed, I would think it a fairly
>safe bet that it is that causing the problem. Ideally you could try another

My mistake; the system was UNARMED from 08:30 until 12:03, so the
spurious data arrived in unarmed state.



Yahoo! Groups Sponsor
ADVERTISEMENT
Height:   4 5 6 7  ft 0 1 2 3 4 5 6 7 8 9 10 11 in
Weight:  
Sex:   F M

For more information: http://www.automatedhome.co.uk
Post message: ukha_d@xxxxxxx
Subscribe:  ukha_d-subscribe@xxxxxxx
Unsubscribe:  ukha_d-unsubscribe@xxxxxxx
List owner:  ukha_d-owner@xxxxxxx

Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.

Home | Main Index | Thread Index

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.