AHA!

Yes, I've seen this happen many times.  It happened to me the first time I
upgraded Homeseer AFTER I'd installed the VB helper service...

What I think is hapenning is that every time you upgrade Homeseer
(including
by just dropping in a new homeseer.exe file with a newer build), the COM
registrations get all mucked up and the VB helper service cannot find the
COM interface for Homeseer...

I'm sure there must be an easier way, but so far the only way I have found
to cure this is to open up the VB source code in the VB dev environment,
and
then remove and re-add the reference to the homeseer object, then
recompiling the EXE.

I mentioned this problem to Rich Helmke, and he modified the Homeseer
version numbering to attempt to prevent this hapenning every time a new
build of the Homeseer.exe file came out, (hence he now uses a
"build" number
instead of incrementing the version number every time), but I don't think
it
has actually had the desired effect...

If you have access to the VB6 dev environment, try opening up the .VBP
file,
then open the Object browser, then select "references" from the
"project"
menu. In the list of available references you will see an item for
Homeseer,
which will be ticked. Untick it, then press the "browse" button,
and browse
to and select your homeseer.exe file. "OK" that, then make a new
.EXE file.
I think that should resolve this problem, - it always has for me.

Of course, if you don't have access to the VB dev environment, then you're
a
bit stuffed! - let me know *exactly* what version (and build no if
applicable) of the homeseer.exe file you're using, ad I'll compile a
version
for you. - but of course, every time you upgrade Homeseer the same problem
will arise again....


Does anyone know if my deduction above re the COM class registrations is
correct, and if so, is there an easier way to correct it? - you may have
deduced that I'm not a developer by trade! - I'm still learning this stuff!

Paul G.





>From: Pedro de Oliveira <oliveirp@xxxxxxx>
>Reply-To: ukha_d@xxxxxxx
>To: "'ukha_d@xxxxxxx'" <ukha_d@xxxxxxx>
>Subject: RE: [ukha_d] Re: Winamp script?
>Date: Wed, 17 Oct 2001 18:27:29 +0100
>
>Hi Paul
>
>I unzipped the files to their respective directories as mentioned in
your
>help file included in the zip file.  The problem is that nothing seems
to
>work - the helper gives an error "Run time error 430: Class does
not
>support
>Automation or does not support expected interface".  When I run
>Project1.exe
>it runs fine and finds winamp as expected.
>I have followed your instructions to the letter (I think) but I stumble
>when
>running homeseerhelper.exe
>I am running Homeseer 1.5.1 and winzip 2.09
>
>Thanks again and sorry for all the bother
>Pedro
>


_________________________________________________________________

Home | Main Index | Thread Index

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.