Re: Homevision Relay boards ... Interested?


  • To: ukha_d@xxxxxxx
  • Subject: Re: Homevision Relay boards ... Interested?
  • From: "Stuart Whyte" <stuart@xxxxxxx>
  • Date: Fri, 12 Oct 2001 23:00:13 -0000
  • Delivered-to: mailing list ukha_d@xxxxxxx
  • Mailing-list: list ukha_d@xxxxxxx; contact ukha_d-owner@xxxxxxx
  • Reply-to: ukha_d@xxxxxxx

I would be interrested in a serial driven model.

S.
--- In ukha_d@y..., "Keith Doxey" <ukha@d...> wrote:
> Why not design a small PCB with 4 relays on it and use a PIC12C508
to dirve
> the relays.
>
> The PIC could be programmed with a base address at programming time
that way
> you wouldnt need any address pins just a few different PIC's
programmed with
> different addresses. The PIC could be programmed for either serial
(1 wire)
> or clocked data (2 wires). That would leave 4 pins for driving the
relays.
>
> PIC12C508 is about a quid.(or less)
>
> Serial data would allow any device capable of RS232 or RS485 to
drive it.
> Clocked data would allow almost anything that could waggle a couple
of data
> lines to drive it at almost any speed. (Homevision, Comfort,
Parallel Port)
>
> Serial or Clocked could be chosen by the PIC that was fitted.
>
> People could order "GP Relay Board <a-nn>"
> where a = C (Clocked) or S (Serial)
> nn = Base address.
>
> When you program the PIC to put in the kit you just choose a
different
> program to load into it.
>
> By using RS485 line drivers/receivers you could put upto 256 of
these boards
> on one cable. By using a PIC you can also do clever things like use
> different codes to do do different thing eg codes 1,2,3,4 turn the
> appropriate relays ON whereas 5,6,7,8 would turn the relays off.
9,10,11,12
> could pulse the relay for 1 second so the board can be used for
either
> momentary or latching purposes.
>
> It would make the board more flexible because it wouldnt just be
limited to
> HomeVision.
>
> Just a few thoughts....keep us informed.
>
> Keith
>
> -----Original Message-----
> From: Phil Harris [mailto:phillip.harris1@xxxxxxx...]
> Sent: 12 October 2001 18:53
> To: ukha_d@y...
> Subject: [ukha_d] Homevision Relay boards ... Interested?
>
>
>
> Hiya Guys,
>
> Ian B and myself have been sitting here this afternoon trying to
design a
> relay board to control my electric curtains ... we thought that
instead of a
> purpose built board to do exatcly what I need it might be useful to
have a
> general purpose relay board.
>
> Throwing around ideas we have come up with the following "rough
description"
> and are wondering whether there would be much interest from the
group for
> this as either a PCB or a built unit.
>
> The board will take up a complete output port on HV. Four of the
port lines
> will be "relay select" lines, a fifth would be a
"status" line
(On/Off) and
> a sixth would be used as a "set" line to get the relay board
to
read the
> output port and perform the requested setting.
>
> For example to turn on relay 4 you'd set the bottom four lines on
the port
> to OFF,ON,OFF,OFF (Binary Coded Decimal for 4), the "status"
line
to ON and
> then the "set" line to ON to action the command.
>
> This would give you sixteen individually addressable relay outputs
that
> would retain their state until changed again or until the power
went off.
>
> It was discussed that the remaining two output lines could be used
as "board
> select" lines which would enable up to 64 individually
addressable
relays to
> be controlled from a single HomeVision output port with the boards
planned
> as being stackable or daisychainable units.
>
> Now, we haven't looked too deeply into this so we have no idea what
kind of
> costs would be involved or even at the moment what the programming
for the
> output ports would be like but we were wondering what kind of
interest there
> would be from the group for such a board if we were to get it
working.
>
> Anyone interested if we decide to progress this further?
>
> Phil
>
>
>
> For more information: http://www.automatedhome.co.uk
> Post message: ukha_d@y...
> Subscribe:  ukha_d-subscribe@y...
> Unsubscribe:  ukha_d-unsubscribe@y...
> List owner:  ukha_d-owner@y...
>
> Your use of Yahoo! Groups is subject to
http://docs.yahoo.com/info/terms/



Home | Main Index | Thread Index

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.