RE: 1-wire Samples


  • To: <ukha_d@xxxxxxx>
  • Subject: RE: 1-wire Samples
  • From: "Graham Kiff" <graham.kiff@xxxxxxx>
  • Date: Fri, 1 Jun 2001 10:48:35 +0100
  • Delivered-to: rich@xxxxxxx
  • Delivered-to: mailing list ukha_d@xxxxxxx
  • Mailing-list: list ukha_d@xxxxxxx; contact ukha_d-owner@xxxxxxx
  • Reply-to: ukha_d@xxxxxxx


>> Do any of the 1-wire devices give light intensity (I'm thinking
>> of daylight sensing for HomeSeer)?

>No, they don't do light sensors, but they do have a/d converters, so
you
>could hook a normal ldr up to one of those and read values from it.

The DS1910 Hygro will measure relative humidity, ambient temperature AND
light intensity.  I've just tried ordering these as part of my 8 product
sample package - not sure if they are in full production on these ones
though.

Graham