Michael

I think I'm getting there (!)

The difference betwen the hallway and lounge, is that I want to be able to get to the kitchen without having to disarm the alarm. Thats why the lounge will set of the alarm / countdown, and not the hall.

I saw some scripts on comforts website to auto-disable - such as for children in the house. Dont think I can use it tho - seems to imply there are two sensors ?

G.
Gareth Cook
Senior Engineering Specialist

EMEA ED, IBM SWG
Lotus Park, Staines, TW18 3AG
Office:  +44 (0) 1784 445 166
Mobile:  +44 (0) 7980 445 166
Fax:      +44 (0) 1784 499 166
Work: g@xxxxxxx
Personal:
g@xxxxxxx
AIM Chat : TheBoyG


----- Forwarded by Gareth Cook/UK/IBM on 06/12/2001 14:21 -----
Discussion
Main Topic

"Michael Mc Aree" <michael.mcaree@xxxxxxx>
Today 14:12

.
Subject:
.
RE: [ukha_d] Understanding Comfort...
.
Category:



> From: Gareth Cook [mailto:g@xxxxxxx]

> OK done the zone list (shall we take this offline ??)

It is ON topic for once !

> Zone1
> Front Door
> Type 2
> Entry Path On
> Response On 248
> Response Off 0

OK Zone 1 is called 'Front Door' and has been determined as part of your
entry path, which means that it won't trigger the alarm instantly as you
enter the house. A preset time is given for you to turn off the alarm.
It has been set as 'Zone Type 2' which is Final Exit Door. This Zone
type will trigger in all modes except 'Security Off'. See Table 8 in the
Work Actions book for details on each Zone Type. The light grey text is
what each zone type actually does. So Zone Type 2 will cause an instant
alarm in 'Away Mode', 'Night Mode' and 'Day Mode'. Still with me? OK now
for the responses; The 'Response On' value and 'Response Off' value are
actually macros that run every time the zone is triggered 'on' or 'off'
(in this case every time your Front Door is open[ON] or closed[OFF]).
Comfort calls these macros "Responses". Therefore your system is set up
so that when Zone 1 triggers 'on' (ie: When your Front Door is open!)
Comfort should execute response 248 (run a macro). The default Comfort
setting has many predefined Responses as seen in Table 33 in the Work
Actions book. Response 248 is spare so your installer must have created
a response and stored it in location 248. What I meant by saying "try
entering in response 59" was to chance the 'on response' value from 248
to 59. If you do this then (I think a reset is required) the nice lady
will say 'Front Door' from the keypad every time your front door is
open. So response 248 looks to be some sort of macro to turn on lights
or something and that is why lights were going on every time you opened
the back door!! I hope this is helping to explain what way your system
is set up, is it?

Do I need to do each zone? Does anyone see anything wrong in my
description?

Gareth - a question for you;
What is the difference between your Hallway Zone setup and your Living
Room Zone Setup? You should have a rough idea by Saturday then you can
play with the alarm during the day.




###############################################
This e-mail, and any attachment, is confidential. If you have received
it in error, please delete it from your system, do not use or disclose
the information in any way, and notify me immediately. The contents of
this message may contain personal views which are not the views of the
company, unless specifically stated.
#################################################


Home | Main Index | Thread Index

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.