|
The UKHA-ARCHIVE IS CEASING OPERATIONS 31 DEC 2024
|
Latest message you have seen: RE: Neat and quiet (but cheap) PCs for home |
[Date Prev][Date
Next][Thread Prev][Thread Next][Date
Index][Thread Index]
RE: Mains Voltage Halogen & LD11
- To: ukha_d@xxxxxxx
- Subject: RE: Mains Voltage Halogen & LD11
- From: Mike Griffiths <mike@xxxxxxx>
- Date: Mon, 27 Aug 2001 01:06:14 +0100
- Delivered-to: rich@xxxxxxx
- Delivered-to: mailing list ukha_d@xxxxxxx
- Mailing-list: list ukha_d@xxxxxxx; contact
ukha_d-owner@xxxxxxx
- Reply-to: ukha_d@xxxxxxx
Thanks Keith
Thought that might be the case
You don't happen to know the part #
I've opened it up but there is nothing written on the Triac
I'll tr and source some fuse holders and fuses at the same time
thanks
Mike
Sent from Home
-----Original Message-----
From: Keith Doxey [mailto:ukha@xxxxxxx]
Sent: Sat 25 Aug 01 15:49
To: ukha_d@xxxxxxx
Subject: RE: [ukha_d] Mains Voltage Halogen & LD11
The triac will be short circuit. Replacing that will restore proper
operation.
The problem is the fuses dont blow quick enought to protect the triac.
You need a hispeed ceramic fuse to protect the triac properly.
Unfortunately
these are 20mm fuses which will not fit the fuseholder on the LD11. You
could fit one in an external holder in series with the output of the LD11.
That should give greater protection.
Keith
> -----Original Message-----
> From: Mike Griffiths [mailto:mike@xxxxxxx]
> Sent: 25 August 2001 13:18
> To: ukha_d@xxxxxxx
> Subject: [ukha_d] Mains Voltage Halogen & LD11
>
>
> Came home last night and a Light circuit MCB had tripped
> A normal occurrence a bulb had blown
> Traced it to a blown 50 watt Mains Voltage Halogen GU10
> There are 4 of these connected to a LD11
> The fuse had blown in this LD11
> The fuse was as black as the ace of spades
> Replaced fuse changed bulb
> LD 11 is stuck on :(
> No control oh dear
> This is the first Mains Voltage Halogen bulb I have had blown of this
type
> I hope this doesn't mean a new LD11 each time
> Anyone else had similar problems ?
> Thanks in advance
>
> Mike
>
> Sent from Home
>
>
>
>
> For more information: http://www.automatedhome.co.uk
> Post message: ukha_d@xxxxxxx
> Subscribe: ukha_d-subscribe@xxxxxxx
> Unsubscribe: ukha_d-unsubscribe@xxxxxxx
> List owner: ukha_d-owner@xxxxxxx
>
> Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/
>
>
>
For more information: http://www.automatedhome.co.uk
Post message: ukha_d@xxxxxxx
Subscribe: ukha_d-subscribe@xxxxxxx
Unsubscribe: ukha_d-unsubscribe@xxxxxxx
List owner: ukha_d-owner@xxxxxxx
Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/
Home |
Main Index |
Thread Index
|
|