At 14:20 29/02/00 +0000, you wrote:
>Mainlight *-------[X10]-----------[Light-Switch]--------[Fuse-Box]
>
>	  *-------[X10]-+
>Halogens
>	  *

Can it change to

Mainlight *-------[X10]-----------[Light-Switch]
\--------[Fuse-Box]
*-------[X10]-+
Halogens
*

If so, the LD10/AD10 DIN rail module would seem to do what you are after,
but you would have to use it with a normal switch instead of a momentary
one.

Does that do what you need?  You could X-10 main or halogen lights on or
off, but the switch would switch both at once (if you used a momentary
switch, and one light was on and one off, it would just keep toggling them
both...

Not being an X-10 expert, I can only say that it should work in theory,
take L from one module to the switch, and send the switch return to both
modules, maybe someone else will actually have tried it... as long as both
are in the same box, it looks like it should be fine.

Nigel


------------------------------------------------------------------------
GET A NEXTCARD VISA, in 30 seconds!  Get rates as low as 0.0%
Intro or 9.9% Fixed APR and no hidden fees.  Apply NOW!
http://click.egroups.com/1/911/3/_/2065/_/951844508/

-- Create a poll/survey for your group!
-- http://www.egroups.com/vote?listname=ukha_d&m=1




Home | Main Index | Thread Index

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.