I do something similar using Comfort and an LD10.  30 Mins after going into
"Night Mode" the landing light is dimmed to a suitable level,
then turned off.  Motion detection just sends an "ON" command
which turns it on at the preset level.  Timer sends an
"OFF" command when expired.  Coming out of "Night Mode"
sends enough brighten commands to restore full brightness.

Adrian





mark@xxxxxxx on 09/08/2000 15:14:46
Please respond to ukha_d@xxxxxxx@SMTP
To:	ukha_d@xxxxxxx@SMTP
cc:
Subject:	Re: [ukha_d] More LD10/11 Questions
Classification:	Restricted
> Are you doing this with your HV or COmfort...

It's a bit round-a-bout Richard but it works really well.  The PIRs are
attached to Comfort.  The new UMC passes the info that the PIR has fired to
ACE.  ACE then sends a command via DDE to HomeVision to run a macro.  The
macro is very simple.  Here's the one for the Hall Lights...


If
Flag #1 (Dark) is set
Then
If
Timer #13 (Downstairs Hall Movement) is running
Then
Load timer #13 (Downstairs Hall Movement) with 0:00:20.00 and start
Else
X-10: A 1 (Hall Halogens) Force Brighten 8 Times
Load timer #13 (Downstairs Hall Movement) with 0:00:20.00 and start
End If
End If

As you can see I never actually send an "ON" command.

The timer then looks like this...

X-10: A 1 (Hall Halogens) Force Dim 8 Times
X-10: A 1 (Hall Halogens) Force Off

> I'm curious how your turning them off and then back on at
> 0%...Everytime I've tried the on action hv brings it on at full

Are you using LD10s or plug in modules Richard?

> Are you taking that at 0% its off or are you actually sending the off
> command?

I dim back down then send an off as above.

M.













--------------------------------------------------------------------<e-
Special Offer-Earn 300 Points from MyPoints.com for trying @Backup
Get automatic protection and access to your important computer files.
Install today:
http://click.egroups.com/1/6347/9/_/2065/_/966340985/
--------------------------------------------------------------------e>-





Home | Main Index | Thread Index

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.