Re: More LD10/11 Questions



> Are you doing this with your HV or COmfort...

It's a bit round-a-bout Richard but it works really well.  The PIRs are
attached to Comfort.  The new UMC passes the info that the PIR has fired to
ACE.  ACE then sends a command via DDE to HomeVision to run a macro.  The
macro is very simple.  Here's the one for the Hall Lights...


If
Flag #1 (Dark) is set
Then
If
Timer #13 (Downstairs Hall Movement) is running
Then
Load timer #13 (Downstairs Hall Movement) with 0:00:20.00 and start
Else
X-10: A 1 (Hall Halogens) Force Brighten 8 Times
Load timer #13 (Downstairs Hall Movement) with 0:00:20.00 and start
End If
End If

As you can see I never actually send an "ON" command.

The timer then looks like this...

X-10: A 1 (Hall Halogens) Force Dim 8 Times
X-10: A 1 (Hall Halogens) Force Off

> I'm curious how your turning them off and then back on at
> 0%...Everytime I've tried the on action hv brings it on at full

Are you using LD10s or plug in modules Richard?

> Are you taking that at 0% its off or are you actually sending the off
> command?

I dim back down then send an off as above.

M.





--------------------------------------------------------------------<e-
Click for more information on how eGroups members save with beMANY!
http://click.egroups.com/1/6780/9/_/2065/_/965830276/
--------------------------------------------------------------------e>-





Home | Main Index | Thread Index

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.